ICON LOFT FIRE RATED STEEL DOORS

Jansen Economy 50 Fire Rated Steel Doors

E30 and E60 Jansen Economy 50 FIRE, fully fire rated steel doors made from steel.

BRE Fire Tested:

  • single (E60) and double (E120) leaf doors
  • side screens and overhead panels available
  • Standard and metallic finish palette
  • Fire Tested hardware
  • Stick-on bars in custom patterns

Data summary

  • 10-12 weeks fabrication time average
  • BRE FIRE tested and approved
  • Test approved by Building Control in the UK
FREE CONSULTATION

with real time pricing


Jansen Economy 50 Fire Rated - technical system overview

100% Steel product

Internal Product

UK BRE Fire Tested


Maximum Clear Opening Dimensions

height (mm)

width (mm)

single door

2500mm

1400mm

double door

2500mm

2650mm

 


Maximum Glass Dimensions

Glass Type

Max Height (mm)

Max Width (mm)

Max Area (m²)

Minutes

Pyroswiss 6 mm

1400

2000

2.80

30 (E30)

Pyroswiss Extra 5–8 mm

2393

1177

2.81

30 (E30)

Pyran S 6 mm

1200

2300

2.76

120 (E120)

Pyrocet 6 mm

1400

2740

3.45

60 (E60)

Pyrobel 21 mm

1196

792

0.86

60 (E60)

Vetroflam 6 mm

1140

2990

3.40

60 (E60)

Contraflam Lite 13 mm

2250

1500

3.37

60–120

Pyroclear 30-001 6 mm

2448

831

2.03

30 (E30)

Pyrotech 630 6 mm

2265

1420

3.22

30 (E30)

Pyroguard EW30 Maxi 11 mm

2748

1674

3.87

30 (E30)

Pyroguard T-EW30 13–19 mm

up to 2530

up to 4000

up to 10.12

30–120


Profile System Dimensions


What can be built?

Single-leaf E50 Fire doors have been fire tested and certified up to 60 minutes. The maximum clear opening for the door leaf is 2500 mm high × 1400 mm wide.

These doors can be installed as standalone units or combined with side panels and rectangular overhead panels to create larger glazed assemblies. The total frame height, including an overpanel, must not exceed 4000 mm. Side panels may be added on one or both sides, with widths determined by the maximum certified glass pane sizes.

By dividing the surrounding fixed panels into multiple panes within the tested glass limits, the system allows for flexible partitions while staying within BRE certification. Arched or shaped overhead panels are not included in the fire test scope and therefore are not permitted in fire-rated configurations.

 

Glass Type

Max Height (mm)

Max Width (mm)

Max Area (m²)

Minutes

Pyroswiss 6 mm

1400

2000

2.80

30

Pyroswiss Extra 5–8 mm

2393

1177

2.81

30

Pyran S 6 mm

1200

2300

2.76

120

Pyrocet 6 mm

1400

2740

3.45

60

Pyrobel 21 mm

1196

792

0.86

60

Vetroflam 6 mm

1140

2990

3.40

60

Contraflam Lite 13 mm

2250

1500

3.37

60–120

Pyroclear 30-001 6 mm

2448

831

2.03

30

Pyrotech 630 6 mm

2265

1420

3.22

30

Pyroguard EW30 Maxi 11 mm

2748

1674

3.87

30

Pyroguard T-EW30 13–19 mm

up to 2530

up to 4000

up to 10.12

30–120

Double-leaf E50 Fire doors are certified for fire resistance up to 120 minutes. The maximum clear opening for the two leaves is 2500 mm high × 2650 mm wide.

These doors can be used on their own or combined with side panels and rectangular overhead panels to form larger glazed assemblies. The total frame height, including an overpanel, must not exceed 4000 mm. Side panels may be fitted on one or both sides, with widths depending on the maximum certified glass pane dimensions.

Large façades or partitions can be achieved by dividing the fixed side and top panels into multiple smaller panes, all within the tested glass size limits. Non-rectangular or arched panels are not included in the BRE fire test scope and are therefore excluded from fire-rated versions.

 

Glass Type

Max Height (mm)

Max Width (mm)

Max Area (m²)

Minutes

Pyroswiss 6 mm

1400

2000

2.80

30

Pyroswiss Extra 5–8 mm

2393

1177

2.81

30

Pyran S 6 mm

1200

2300

2.76

120

Pyrocet 6 mm

1400

2740

3.45

60

Pyrobel 21 mm

1196

792

0.86

60

Vetroflam 6 mm

1140

2990

3.40

60

Contraflam Lite 13 mm

2250

1500

3.37

60–120

Pyroclear 30-001 6 mm

2448

831

2.03

30

Pyrotech 630 6 mm

2265

1420

3.22

30

Pyroguard EW30 Maxi 11 mm

2748

1674

3.87

30

Pyroguard T-EW30 13–19 mm

up to 2530

up to 4000

up to 10.12

30–120


Mandatory equipment

Mandatory Accessories – E50 Fire

  • Locks & Latches
    • Single-leaf: single-point latch
    • Double-leaf:
      • single-point latch + shoot bolts, or
      • two-point latch (mandatory for 120 min)
  • Hinges
    • Minimum 2 hinges per leaf
    • Tested hinge types only (weld-on, screw-on, concealed, offset)
    • Dog bolt between hinge positions
  • Door Closers
    • Fire-rated surface closer or floor spring
    • Double-leaf: closer with selector mechanism

SYSTEM OVERVIEW
  • Mild or stainless steel frames
  • Single-acting doorsets (single-leaf or double-leaf)
  • Fixed glazed screens with optional overpanels/side screens
  • Single- and double-glazed units available
Technical Configuration
  • Anchored to masonry/concrete with M8 expanding steel anchors
  • Anchors at 800 mm nominal centers
  • Thermal expansion gap: 20 mm filled with mineral wool (60 kg/m³)
  • Max frame height: 4000 mm
  • Redesigned glazing beads (size, thickness, and fixing method remain as previously tested)
  • Supporting construction must meet or exceed the fire resistance of the system
CLEAR OPENING SIZES
  • Single-leaf doorsets:
    Max clear opening height: 2500 mm
    Max clear opening width: 1400 mm

  • Double-leaf doorsets:
    Max clear opening height: 2500 mm
    Max clear opening width: 2650 mm

LOCKING SYSTEMS
  • Single-leaf: Single-point latch

  • Double-leaf:

    • Active leaf: single or two-point latch
    • Passive leaf: spring-loaded shoot bolt (optional with two-point latch)
  • For 120-min doorsets:
    Two-point latch on active leaf is mandatory

  • All doorsets must latch automatically during fire conditions

HINGES
  • Minimum 2 hinges per leaf
  • Additional hinges allowed for heavy or high-traffic doors
  • Types permitted:
    • Surface-mounted weld-on
    • Surface-mounted screw-on
    • Concealed rebate fitted
    • Offset hinges with floor-mounted closers
  • Dog bolt required between hinge points
CLOSERS
  • Mandatory fire-rated door closers (surface-mounted or floor springs)
  • Double-leaf doorsets: must include a selector mechanism

Full glass list:

Opening type possibilities:

Single hinged doors w/ or without fixed panels

Double hinged doors w/ or without fixed panels


Other products you might like

Icon Loft Slim Steel Doors

Our best selling and slimmest steel doors profile system.

SEE

Icon Loft Pro Steel Doors

Our second best selling steel doors system.

SEE

Jansen Economy 50 Fire Rated Steel Doors

Robust Fire Rated steel doors system.

SEE

Ottostumm W40 Fire

Classic design and Fire Certification.

SEE

Want to know how much your business can gain from

importing steel doors from Poland?

Free consulatation

with real time pricing